Pith. sign in

REVIEW

A high time resolution study of the millisecond pulsar J2241-5236 at frequencies below 300 MHz

Not yet reviewed by Pith; the record is open.

This paper has not been read by Pith yet. Machine review is queued; the pith claim, tier, and objections will appear here once it completes.

SPECIMEN: schema-true, not a live event

T0 review · schema-true

One-sentence machine reading of the paper's core claim.

pith:XXXXXXXX · record.json · timestamp

arxiv 1907.08916 v1 pith:A56EL2T7 submitted 2019-07-21 astro-ph.HE astro-ph.IM

A high time resolution study of the millisecond pulsar J2241-5236 at frequencies below 300 MHz

classification astro-ph.HE astro-ph.IM
keywords timedatafrequenciesobservationspulsarpulsarsresolutiontiming
verification ladder T0 review T1 audit T2 compute T3 formal T4 reserved
0 comments
read the original abstract

One of the major challenges for pulsar timing array (PTA) experiments is the mitigation of the effects of the turbulent interstellar medium (ISM) from timing data. These can potentially lead to measurable delays and/or distortions in the pulse profiles and scale strongly with the inverse of the radio frequency. Low-frequency observations are therefore highly appealing for characterizing them. However, in order to achieve the necessary time resolution to resolve profile features of short-period millisecond pulsars, phase-coherent de-dispersion is essential, especially at frequencies below $300$ MHz. We present the lowest-frequency ($80$-$220$ MHz), coherently de-dispersed detections of one of the most promising pulsars for current and future PTAs, PSR J2241$-$5236, using our new beam-former software for the MWA's voltage capture system (VCS), which reconstructs the time series at a much higher time resolution of $\sim 1 \mu$s by re-synthesizing the recorded voltage data at $10$-kHz/$100$-$\mu$s native resolutions. Our data reveal a dual-precursor type feature in the pulse profile that is either faint or absent in high-frequency observations from Parkes. The resultant high-fidelity detections have enabled dispersion measure (DM) determinations with very high precision, of the order of $(2$-$6)\times10^{-6}$ $\rm pc\,cm^{-3}$, owing to the microsecond level timing achievable for this pulsar at the MWA's low frequencies. This underscores the usefulness of low-frequency observations for probing the ISM toward PTA pulsars and informing optimal observing strategies for PTA experiments.

discussion (0)

Sign in with ORCID, Apple, or X to comment. Anyone can read and Pith papers without signing in.