Pith. sign in

REVIEW

Experimental benchmark data for Monte Carlo simulated radiation effects of gold nanoparticles. Part II: Comparison of measured and simulated electron spectra from gold nanofoils

Not yet reviewed by Pith; the record is open.

This paper has not been read by Pith yet. Machine review is queued; the pith claim, tier, and objections will appear here once it completes.

SPECIMEN: schema-true, not a live event

T0 review · schema-true

One-sentence machine reading of the paper's core claim.

pith:XXXXXXXX · record.json · timestamp

arxiv 2212.07367 v2 pith:6UJJZV73 submitted 2022-12-14 physics.med-ph cond-mat.otherphysics.comp-ph

Experimental benchmark data for Monte Carlo simulated radiation effects of gold nanoparticles. Part II: Comparison of measured and simulated electron spectra from gold nanofoils

classification physics.med-ph cond-mat.otherphysics.comp-ph
keywords photonelectronenergiesgoldwerecarlodataexperiments
verification ladder T0 review T1 audit T2 compute T3 formal T4 reserved
0 comments
read the original abstract

Electron emission spectra of a thin gold foil after photon interaction were measured over the energy range between 50 eV and 9500 eV to provide reference data for Monte Carlo radiation-transport simulations. Experiments were performed with the HAXPES spectrometer at the PETRA III high-brilliance beamline P22 at DESY (Hamburg, Germany) for photon energies just below and above each of the gold L-edges, i.e., at 11.9 keV, 12.0 keV, 13.7 keV, 13.8 keV, 14.3 keV, and 14.4 keV. The data were analyzed to obtain the absolute values of the particle radiance of the emitted electrons per incident photon flux. Simulations of the experiment were performed using the Monte Carlo radiation-transport codes Penelope and Geant4. Comparison of the measured and simulated results shows good qualitative agreement. When simulation results are convolved with curves that take into account the effect of lifetime broadening, line shapes of photoelectron and Auger peaks similar to those observed experimentally are obtained. On an absolute scale, the experiments tend to give higher electron radiance values at the lower photon energies studied as well as at the higher photon energies for electron energies below the energy of the Au L3 photoelectron. This is attributed to the linear polarization of the photon beam in the experiments which is not considered in the simulation codes.

discussion (0)

Sign in with ORCID, Apple, or X to comment. Anyone can read and Pith papers without signing in.