Pith. sign in

REVIEW 1 cited by

Material radiopurity control in the XENONnT experiment

Not yet reviewed by Pith; the record is open.

This paper has not been read by Pith yet. Machine review is queued; the pith claim, tier, and objections will appear here once it completes.

SPECIMEN: schema-true, not a live event

T0 review · schema-true

One-sentence machine reading of the paper's core claim.

pith:XXXXXXXX · record.json · timestamp

arxiv 2112.05629 v2 pith:IHNYXPLB submitted 2021-12-10 physics.ins-det astro-ph.IM

Material radiopurity control in the XENONnT experiment

E. Aprile , K. Abe , F. Agostini , S. Ahmed Maouloud , M. Alfonsi , L. Althueser , E. Angelino , J. R. Angevaare
show 145 more authors
V. C. Antochi D. Ant\'on Martin F. Arneodo L. Baudis A. L. Baxter L. Bellagamba R. Biondi A. Bismark A. Brown S. Bruenner G. Bruno R. Budnik C. Capelli J. M. R. Cardoso D. Cichon B. Cimmino M. Clark A. P. Colijn J. Conrad J. J. Cuenca-Garc\'ia J. P. Cussonneau V. D'Andrea M. P. Decowski P. Di Gangi S. Di Pede A. Di Giovanni R. Di Stefano S. Diglio A. Elykov S. Farrell A. D. Ferella H. Fischer W. Fulgione P. Gaemers R. Gaior M. Galloway F. Gao R. Glade-Beucke L. Grandi J. Grigat A. Higuera C. Hils K. Hiraide L. Hoetzsch J. Howlett M. Iacovacci Y. Itow J. Jakob F. Joerg N. Kato P. Kavrigin S. Kazama M. Kobayashi G. Koltman A. Kopec H. Landsman R. F. Lang L. Levinson I. Li S. Liang S. Lindemann M. Lindner K. Liu F. Lombardi J. Long J. A. M. Lopes Y. Ma C. Macolino J. Mahlstedt A. Mancuso L. Manenti A. Manfredini F. Marignetti T. Marrod\'an Undagoitia K. Martens J. Masbou D. Masson E. Masson S. Mastroianni M. Messina K. Miuchi K. Mizukoshi A. Molinario S. Moriyama K. Mor{\aa} Y. Mosbacher M. Murra K. Ni U. Oberlack J. Palacio R. Peres J. Pienaar M. Pierre V. Pizzella G. Plante J. Qi J. Qin D. Ram\'irez Garc\'ia S. Reichard A. Rocchetti N. Rupp L. Sanchez J. M. F. dos Santos G. Sartorelli J. Schreiner D. Schulte H. Schulze Ei{\ss}ing M. Schumann L. Scotto Lavina M. Selvi F. Semeria P. Shagin E. Shockley M. Silva H. Simgen A. Takeda P.-L. Tan A. Terliuk C. Therreau D. Thers F. Toschi G. Trinchero C. Tunnell F. T\"onnies K. Valerius G. Volta Y. Wei C. Weinheimer M. Weiss D. Wenz J. Westermann C. Wittweg T. Wolf Z. Xu M. Yamashita L. Yang J. Ye L. Yuan G. Zavattini Y. Zhang M. Zhong T. Zhu J. P. Zopounidis M. Laubenstein S. Nisi
This is my paper
classification physics.ins-det astro-ph.IM
keywords xenonntmaterialsradonconcentrationemanationexperimentmaterialmeasurements
verification ladder T0 review T1 audit T2 compute T3 formal T4 reserved
0 comments
read the original abstract

The selection of low-radioactive construction materials is of the utmost importance for rare-event searches and thus critical to the XENONnT experiment. Results of an extensive radioassay program are reported, in which material samples have been screened with gamma-ray spectroscopy, mass spectrometry, and $^{222}$Rn emanation measurements. Furthermore, the cleanliness procedures applied to remove or mitigate surface contamination of detector materials are described. Screening results, used as inputs for a XENONnT Monte Carlo simulation, predict a reduction of materials background ($\sim$17%) with respect to its predecessor XENON1T. Through radon emanation measurements, the expected $^{222}$Rn activity concentration in XENONnT is determined to be 4.2$\,(^{+0.5}_{-0.7})\,\mu$Bq/kg, a factor three lower with respect to XENON1T. This radon concentration will be further suppressed by means of the novel radon distillation system.

discussion (0)

Sign in with ORCID, Apple, or X to comment. Anyone can read and Pith papers without signing in.

Forward citations

Cited by 1 Pith paper

Reviewed papers in the Pith corpus that reference this work. Sorted by Pith novelty score.

  1. Proof-of-concept of a xenon-based cryogenic heat pump demonstrator for future liquid xenon observatories

    physics.ins-det 2025-11 conditional novelty 7.0

    A hermetically sealed xenon heat pump demonstrator provides 118 W cooling and 121 W heating at 386 W electrical input, sufficient for 3.1 kg/h xenon purification flow and far below the 6 kW of existing helium-based systems.