Pith. sign in

REVIEW 1 cited by

Characterization of the Hamamatsu R11780 12 inch Photomultiplier Tube

Not yet reviewed by Pith; the record is open.

This paper has not been read by Pith yet. Machine review is queued; the pith claim, tier, and objections will appear here once it completes.

SPECIMEN: schema-true, not a live event

T0 review · schema-true

One-sentence machine reading of the paper's core claim.

pith:XXXXXXXX · record.json · timestamp

arxiv 1210.2765 v2 pith:KEVNBAJ3 submitted 2012-10-09 physics.ins-det hep-exnucl-ex

Characterization of the Hamamatsu R11780 12 inch Photomultiplier Tube

classification physics.ins-det hep-exnucl-ex
keywords efficiencyquantumdetectorshighr11780standardcandidatecherenkov
verification ladder T0 review T1 audit T2 compute T3 formal T4 reserved
0 comments
read the original abstract

Future large water Cherenkov and scintillator detectors have been proposed for measurements of long baseline neutrino oscillations, proton decay, supernova and solar neutrinos. To ensure cost-effectiveness and optimize scientific reach, one of the critical requirements for such detectors are large-area, high performance photomultiplier tubes (PMTs). One candidate for such a device is the Hamamatsu R11780, a 12" PMT that is available in both standard and high quantum efficiency versions. Measurements of the single photoelectron response characteristics, relative efficiencies of the standard and high quantum efficiency versions, a preliminary measurement of the absolute quantum efficiency of the standard quantum efficiency version, and a two-dimensional scan of the relative efficiency across the photocathode surface are presented in this paper. All single photoelectron investigations were made using a Cherenkov light source at room temperature at a gain of 1*10^7. These results show that the R11780 PMT is a excellent candidate for such large optical detectors, including the peak-to-valley ratios greater than 2, transit time spreads around 1.3 ns, and late-pulsing probabilities less than 5%.

discussion (0)

Sign in with ORCID, Apple, or X to comment. Anyone can read and Pith papers without signing in.

Forward citations

Cited by 1 Pith paper

Reviewed papers in the Pith corpus that reference this work. Sorted by Pith novelty score.

  1. Performance of the Eos detector with water

    hep-ex 2026-06 unverdicted novelty 4.0

    First calibration results from the Eos four-tonne water Cherenkov detector validate simulations and reconstruction methods using deployed optical and radioactive sources.