Precise magnetization measurements down to 500 mK using a miniature 3He cryostat and a closed-cycle 3He gas handling system installed in a SQUID magnetometer without continuous-cooling functionality
read the original abstract
We have conducted precise magnetization measurements down to 0.5 K with a miniature 3He cryostat and a closed-cycle 3He gas handling system for a commercial superconducting quantum interference device magnetometer [Magnetic Property Measurement System (Quantum Design)]. The gas handling system contains two sorption pumps filled with granular charcoals. We pressurize 3He gas up to ambient pressure for the liquification at 3 K and then pump the vaper for cooling. The lowest sample temperature is ~ 0.5 K and it can persist for 34 hours. We demonstrate the performance of the system by observing the Meissner effect of aluminum below the superconducting transition temperature ~ 1 K. We also measured the magnetization curve of the heavy fermion superconductor CeCoIn5 resulting in successful observation of the lower critical field at 0.5 K.
This paper has not been read by Pith yet.
discussion (0)
Sign in with ORCID, Apple, or X to comment. Anyone can read and Pith papers without signing in.