Pith. sign in

REVIEW

Description and stability of a RPC-based calorimeter in electromagnetic and hadronic shower environments

Not yet reviewed by Pith; the record is open.

This paper has not been read by Pith yet. Machine review is queued; the pith claim, tier, and objections will appear here once it completes.

SPECIMEN: schema-true, not a live event

T0 review · schema-true

One-sentence machine reading of the paper's core claim.

pith:XXXXXXXX · record.json · timestamp

arxiv 2207.06291 v2 pith:TLPVFJWH submitted 2022-07-13 physics.ins-det

Description and stability of a RPC-based calorimeter in electromagnetic and hadronic shower environments

classification physics.ins-det
keywords detectorcalorimeterprototypealgorithmbeamconditionsdata-takingdescribes
verification ladder T0 review T1 audit T2 compute T3 formal T4 reserved
0 comments
read the original abstract

The CALICE Semi-Digital Hadron Calorimeter technological prototype completed in 2011 is a sampling calorimeter using Glass Resistive Plate Chamber (GRPC) detectors as the active medium. This technology is one of the two options proposed for the hadron calorimeter of the International Large Detector for the International Linear Collider. The prototype was exposed in 2015 to beams of muons, electrons, and pions of different energies at the CERN Super Proton Synchrotron. The use of this technology for future experiments requires a reliable simulation of its response that can predict its performance. GEANT4 combined with a digitization algorithm was used to simulate the prototype. It describes the full path of the signal: showering, gas avalanches, charge induction, and hit triggering. The simulation was tuned using muon tracks and electromagnetic showers for accounting for detector inhomogeneity and tested on hadronic showers collected in the test beam. This publication describes developments of the digitization algorithm. It is used to predict the stability of the detector performance against various changes in the data-taking conditions, including temperature, pressure, magnetic field, GRPC width variations, and gas mixture variations. These predictions are confronted with test beam data and provide an attempt to explain the detector properties. The data-taking conditions such as temperature and potential detector inhomogeneities affect energy density measurements but have a small impact on detector efficiency.

discussion (0)

Sign in with ORCID, Apple, or X to comment. Anyone can read and Pith papers without signing in.