Pith. sign in

REVIEW 1 cited by

Batch test of MRPC3b for CBM-TOF/STAR-eTOF

Not yet reviewed by Pith; the record is open.

This paper has not been read by Pith yet. Machine review is queued; the pith claim, tier, and objections will appear here once it completes.

SPECIMEN: schema-true, not a live event

T0 review · schema-true

One-sentence machine reading of the paper's core claim.

pith:XXXXXXXX · record.json · timestamp

arxiv 2308.16556 v1 pith:42P52SFA submitted 2023-08-31 physics.ins-det

Batch test of MRPC3b for CBM-TOF/STAR-eTOF

classification physics.ins-det
keywords testcbm-tofbatchbeenmrpc3bstar-etofstripsaround
verification ladder T0 review T1 audit T2 compute T3 formal T4 reserved
0 comments
read the original abstract

The Compressed Baryonic Matter (CBM) experiment is one of the major scientific spectrometers of the future Facility for Antiproton and Ion Research (FAIR) in Darmstadt. As one of the core sub-systems in CBM experiment for charged hadron identification, the Time-of-Flight (TOF) system is required to have a time resolution better than 80 ps. According to the final state particle flux distribution, the CBM-TOF will be constructed with several types of Multigap Resistive Plate Chambers (MRPC). In the outer region of the TOF wall where the particle fluxes are around 1 kHz/cm2, MRPCs with ultra-thin float glass electrodes are considered as a cost effective solution. MRPC3b prototypes have been developed and tested with excellent performance which could meet all the requirements. Before the construction of CBM-TOF, approximately 80 MRPC3bs are assembled for the STAR endcap TOF (STAR-eTOF) upgrade at RHIC as part of the FAIR Phase-0 programs for CBM-TOF which provides a valuable opportunity for detector stability test under high flux environments. This paper will introduce the batch test of the MRPC3bs for STAR-eTOF upgrade. Time resolution of better than 70 ps and efficiency of around 95% are achieved. Notably, during the batch test, it has been observed that the noise rates of the two edge strips in each counter are significantly higher than those of the middle strips. Simulations with Computer Simulation Technology (CST)Studio Suite are carried out and several kinds of MRPC prototypes are designed and tested accordingly. Based on the simulation and test results, the design of the MRPC3b has been further optimized, resulting in a significant suppression of noise rates in the edge strips.

discussion (0)

Sign in with ORCID, Apple, or X to comment. Anyone can read and Pith papers without signing in.

Forward citations

Cited by 1 Pith paper

Reviewed papers in the Pith corpus that reference this work. Sorted by Pith novelty score.

  1. Elliptic Flow of Multi-strange Hadrons in Au+Au Collisions at $\sqrt{s_{NN}}$ = 7.7-19.6 GeV

    nucl-ex 2026-05 conditional novelty 6.0

    New precision v2 measurements show NCQ scaling holds for multi-strange hadrons down to 7.7 GeV, supporting partonic origin of elliptic flow with minimal late-stage distortion.