REVIEW 1 cited by
First Results from HERA Phase I: Upper Limits on the Epoch of Reionization 21 cm Power Spectrum
Not yet reviewed by Pith; the record is open.
This paper has not been read by Pith yet. Machine review is queued; the pith claim, tier, and objections will appear here once it completes.
SPECIMEN: schema-true, not a live event
T0 review · schema-true
One-sentence machine reading of the paper's core claim.
pith:XXXXXXXX · record.json · timestamp
First Results from HERA Phase I: Upper Limits on the Epoch of Reionization 21 cm Power Spectrum
read the original abstract
We report upper-limits on the Epoch of Reionization (EoR) 21 cm power spectrum at redshifts 7.9 and 10.4 with 18 nights of data ($\sim36$ hours of integration) from Phase I of the Hydrogen Epoch of Reionization Array (HERA). The Phase I data show evidence for systematics that can be largely suppressed with systematic models down to a dynamic range of $\sim10^9$ with respect to the peak foreground power. This yields a 95% confidence upper limit on the 21 cm power spectrum of $\Delta^2_{21} \le (30.76)^2\ {\rm mK}^2$ at $k=0.192\ h\ {\rm Mpc}^{-1}$ at $z=7.9$, and also $\Delta^2_{21} \le (95.74)^2\ {\rm mK}^2$ at $k=0.256\ h\ {\rm Mpc}^{-1}$ at $z=10.4$. At $z=7.9$, these limits are the most sensitive to-date by over an order of magnitude. While we find evidence for residual systematics at low line-of-sight Fourier $k_\parallel$ modes, at high $k_\parallel$ modes we find our data to be largely consistent with thermal noise, an indicator that the system could benefit from deeper integrations. The observed systematics could be due to radio frequency interference, cable sub-reflections, or residual instrumental cross-coupling, and warrant further study. This analysis emphasizes algorithms that have minimal inherent signal loss, although we do perform a careful accounting in a companion paper of the small forms of loss or bias associated with the pipeline. Overall, these results are a promising first step in the development of a tuned, instrument-specific analysis pipeline for HERA, particularly as Phase II construction is completed en route to reaching the full sensitivity of the experiment.
Forward citations
Cited by 1 Pith paper
-
A self-consistent analytical model for both the photoionization rate and reionization history
A new analytical formalism self-consistently predicts both the ionized fraction x_i(z) and photoionization rate Gamma_HI(z), achieving percent-level accuracy in x_i and 20-30% accuracy in Gamma_HI versus radiative tra...
discussion (0)
Sign in with ORCID, Apple, or X to comment. Anyone can read and Pith papers without signing in.