pith. sign in

arxiv: 1812.11426 · v2 · pith:ZQZGK775new · submitted 2018-12-29 · ⚛️ physics.ins-det

Performance and Moli`ere radius measurements using a compact prototype of LumiCal in an electron test beam

classification ⚛️ physics.ins-det
keywords compactdetectorelectronlumicalmoliprototyperadiusbeam
0
0 comments X
read the original abstract

A new design of a detector plane of sub-millimetre thickness for an electromagnetic sampling calorimeter is presented. It is intended to be used in the luminometers LumiCal and BeamCal in future linear $e^+e^-$ collider experiments. The detector planes were produced utilising novel connectivity scheme technologies. They were installed in a compact prototype of the calorimeter and tested at DESY with an electron beam of energy 1-5 GeV. The performance of a prototype of a compact LumiCal comprising eight detector planes was studied. The effective Moli`ere radius at 5 GeV was determined to be (8.1 +/- 0.1 (stat) +/- 0.3 (syst)) mm, a value well reproduced by the Monte Carlo (MC) simulation (8.4 +/- 0.1) mm. The dependence of the effective Moli`ere radius on the electron energy in the range 1-5 GeV was also studied. Good agreement was obtained between data and MC simulation.

This paper has not been read by Pith yet.

discussion (0)