REVIEW 4 cited by
Systematic effects in LOFAR data: A unified calibration strategy
Not yet reviewed by Pith; the record is open.
This paper has not been read by Pith yet. Machine review is queued; the pith claim, tier, and objections will appear here once it completes.
SPECIMEN: schema-true, not a live event
T0 review · schema-true
One-sentence machine reading of the paper's core claim.
pith:XXXXXXXX · record.json · timestamp
Systematic effects in LOFAR data: A unified calibration strategy
read the original abstract
Context: New generation low-frequency telescopes are exploring a new parameter space in terms of depth and resolution. The data taken with these interferometers, for example with the LOw Frequency ARray (LOFAR), are often calibrated in a low signal-to-noise ratio regime and the removal of critical systematic effects is challenging. The process requires an understanding of their origin and properties. Aim: In this paper we describe the major systematic effects inherent to next generation low-frequency telescopes, such as LOFAR. With this knowledge, we introduce a data processing pipeline that is able to isolate and correct these systematic effects. The pipeline will be used to calibrate calibrator observations as the first step of a full data reduction process. Methods: We processed two LOFAR observations of the calibrator 3C196: the first using the Low Band Antenna (LBA) system at 42-66 MHz and the second using the High Band Antenna (HBA) system at 115-189 MHz. Results: We were able to isolate and correct for the effects of clock drift, polarisation misalignment, ionospheric delay, Faraday rotation, ionospheric scintillation, beam shape, and bandpass. The designed calibration strategy produced the deepest image to date at 54 MHz. The image has been used to confirm that the spectral energy distribution of the average radio source population tends to flatten at low frequencies. Conclusions: We prove that LOFAR systematic effects can be described by a relatively small number of parameters. Furthermore, the identification of these parameters is fundamental to reducing the degrees of freedom when the calibration is carried out on fields that are not dominated by a strong calibrator.
Forward citations
Cited by 4 Pith papers
-
Polarisation and Faraday rotation measure imaging at metre wavelengths with sub-arcsecond resolution: a foundational calibration strategy
A calibration strategy using full-Jones corrections with an in-field unpolarised calibrator and visibility-based multi-epoch alignment enables sub-arcsecond polarimetric imaging with LOFAR at metre wavelengths.
-
The ultra low-frequency spectral properties of bright extended radio galaxies in the 3CRR catalogue
Presents ultra-low frequency spectral index maps for 22 bright extended radio galaxies showing indices of ~0.5 near cores rising to >1.0 in lobes for FR I sources and 0.5-0.9 in FR II hotspots.
-
Studying Ionospheric Phase Structure Functions Using Wide-Band uGMRT (Band-4) Interferometric Data
uGMRT Band-4 data on 3C48 show ionospheric phase structure functions with power-law turbulence, diffractive scales of 6.7-8.3 km, and anisotropy consistent with MSTIDs at ~19°N latitude.
-
Early phases of star formation with SKAO: synchrotron emission from dense starless cores in molecular clouds
SKAO will enable detection of synchrotron emission from prestellar cores to probe their magnetic field properties in nearby star-forming regions.
discussion (0)
Sign in with ORCID, Apple, or X to comment. Anyone can read and Pith papers without signing in.