Pith. sign in

REVIEW

CSSTag: Optical Nanoscale Radar and Particle Tracking for In-Body and Microfluidic Systems with Vibrating Graphene and Resonance Energy Transfer

Not yet reviewed by Pith; the record is open.

This paper has not been read by Pith yet. Machine review is queued; the pith claim, tier, and objections will appear here once it completes.

SPECIMEN: schema-true, not a live event

T0 review · schema-true

One-sentence machine reading of the paper's core claim.

pith:XXXXXXXX · record.json · timestamp

arxiv 1709.00907 v1 pith:KNSGYWKV submitted 2017-09-04 q-bio.QM cs.CV

CSSTag: Optical Nanoscale Radar and Particle Tracking for In-Body and Microfluidic Systems with Vibrating Graphene and Resonance Energy Transfer

classification q-bio.QM cs.CV
keywords trackingnanoscaleparticlesystemscapabilitygraphenemicrofluidicmodulator
verification ladder T0 review T1 audit T2 compute T3 formal T4 reserved
0 comments
read the original abstract

Single particle tracking systems monitor cellular processes with great accuracy in nano-biological systems. The emissions of the fluorescent molecules are detected with cameras or photodetectors. However, state-of-the-art imaging systems have challenges in the detection capability, collection and analysis of imaging data, penetration depth and complicated set-ups. In this article, a \textit{signaling based nanoscale acousto-optic radar and microfluidic particle tracking system} is proposed based on the theoretical design providing nanoscale optical modulator with vibrating F{\"{o}}rster resonance energy transfer (VFRET) and vibrating CdSe/ZnS quantum dots (QDs) on graphene resonators. The modulator structure combines the significant advantages of graphene membranes having wideband resonance frequencies with QDs having broad absorption spectrum and tunable properties. The solution denoted by chirp spread spectrum (CSS) Tag (\textit{CSSTag}) utilizes classical radar target tracking approaches in nanoscale environments based on the capability to generate CSS sequences to identify different bio-particles. Numerical and Monte-Carlo simulations are realized showing the significant performance for multiple particle tracking (MPT) with a modulator of $10 \, \mu$m $\times$ $10 \, \mu$m $\times$ $10 \, \mu$m dimension and several picograms of weight, signal to noise ratio (SNR) in the range $-7$ dB to $10$ dB and high speed tracking capability for microfluidic and in-body environments.

discussion (0)

Sign in with ORCID, Apple, or X to comment. Anyone can read and Pith papers without signing in.