Pith. sign in

REVIEW

Detection of CO and HCN in Pluto's atmosphere with ALMA

Not yet reviewed by Pith; the record is open.

This paper has not been read by Pith yet. Machine review is queued; the pith claim, tier, and objections will appear here once it completes.

SPECIMEN: schema-true, not a live event

T0 review · schema-true

One-sentence machine reading of the paper's core claim.

pith:XXXXXXXX · record.json · timestamp

arxiv 1606.03293 v2 pith:VRSEZPG4 submitted 2016-06-10 astro-ph.EP

Detection of CO and HCN in Pluto's atmosphere with ALMA

classification astro-ph.EP
keywords atmosphereplutotemperatureupperdetectionfractionmoleabove
verification ladder T0 review T1 audit T2 compute T3 formal T4 reserved
0 comments
read the original abstract

Observations of the Pluto-Charon system, acquired with the ALMA interferometer on June 12-13, 2015, have yielded a detection of the CO(3-2) and HCN(4-3) rotational transitions from Pluto, providing a strong confirmation of the presence of CO, and the first observation of HCN, in Pluto's atmosphere. The CO and HCN lines probe Pluto's atmosphere up to ~450 km and ~900 km altitude, respectively. The CO detection yields (i) a much improved determination of the CO mole fraction, as 515+/-40 ppm for a 12 ubar surface pressure (ii) clear evidence for a well-marked temperature decrease (i.e., mesosphere) above the 30-50 km stratopause and a best-determined temperature of 70+/-2 K at 300 km, in agreement with recent inferences from New Horizons / Alice solar occultation data. The HCN line shape implies a high abundance of this species in the upper atmosphere, with a mole fraction >1.5x10-5 above 450 km and a value of 4x10-5 near 800 km. The large HCN abundance and the cold upper atmosphere imply supersaturation of HCN to a degree (7-8 orders of magnitude) hitherto unseen in planetary atmospheres, probably due to the slow kinetics of condensation at the low pressure and temperature conditions of Pluto's upper atmosphere. HCN is also present in the bottom ~100 km of the atmosphere, with a 10-8 - 10-7 mole fraction; this implies either HCN saturation or undersaturation there, depending on the precise stratopause temperature. The HCN column is (1.6+/-0.4)x10^14 cm-2, suggesting a surface-referred net production rate of ~2x10^7 cm-2s-1. Although HCN rotational line cooling affects Pluto's atmosphere heat budget, the amounts determined in this study are insufficient to explain the well-marked mesosphere and upper atmosphere's ~70 K temperature. We finally report an upper limit on the HC3N column density (< 2x10^13 cm-2) and on the HC15N / HC14N ratio (< 1/125).

discussion (0)

Sign in with ORCID, Apple, or X to comment. Anyone can read and Pith papers without signing in.