Pith. sign in

REVIEW

Effects of diode laser photobiomodulation on peri-implant inflammation and stability in orthodontic mini-implants: A randomized controlled trial

Not yet reviewed by Pith; the record is open.

This paper has not been read by Pith yet. Machine review is queued; the pith claim, tier, and objections will appear here once it completes.

SPECIMEN: schema-true, not a live event

T0 review · schema-true

One-sentence machine reading of the paper's core claim.

pith:XXXXXXXX · record.json · timestamp

arxiv 2511.11128 v1 pith:PAUPZICH submitted 2025-11-14 physics.med-ph q-bio.BM

Effects of diode laser photobiomodulation on peri-implant inflammation and stability in orthodontic mini-implants: A randomized controlled trial

classification physics.med-ph q-bio.BM
keywords groupperi-implantdiodeexperimentallaserorthodonticeffectsmini-implants
verification ladder T0 review T1 audit T2 compute T3 formal T4 reserved
0 comments
read the original abstract

Peri-implant inflammation in orthodontic mini-implant may lead to patient discomfort and treatment failure. This study aims to evaluate the effects of diode laser application on the health of mini-implant, preventing peri-implantitis and promoting healing. A randomized controlled trial was conducted involving 30 orthodontic patients (12 males and 18 females, aged 18-32) who had mini-implants implanted on both sides of the maxilla for anterior teeth retraction. One side of each patient was assigned to either an experimental group receiving diode laser irradiation (650 nm, 25 mW) at specific postoperative intervals or a control group receiving simulated radiation. Clinical assessments included plaque index, modified sulcus bleeding index, probing depth, and incidence of peri-implant mucositis and implant mobility, measured at 1, 4, and 12 weeks post-implantation. Additionally, interleukin-1 beta (IL-1\b{eta}) levels in peri-implant fluid were analyzed via enzyme-linked immunosorbent assay (ELISA). Results indicated that the experimental group exhibited significantly lower plaque indices, sulcus bleeding indices, and probing depths (p < 0.05) compared to the control group. Moreover, the experimental group had fewer cases of peri-implant mucositis (p < 0.05), while differences in implant stability were not statistically significant (p > 0.05). IL-1\b{eta} levels were consistently lower in the experimental group throughout the study duration (p < 0.05). In conclusion, adjunctive diode laser therapy appears to enhance peri-implant health and reduce complications associated with orthodontic mini-implants, suggesting a promising direction for improving patient outcomes in orthodontics. Future research should explore long-term effects and the mechanisms underlying these benefits.

discussion (0)

Sign in with ORCID, Apple, or X to comment. Anyone can read and Pith papers without signing in.