Pith. sign in

REVIEW

Mechanical Ventilator Milano (MVM): A Novel Mechanical Ventilator Designed for Mass Scale Production in Response to the COVID-19 Pandemic

Not yet reviewed by Pith; the record is open.

This paper has not been read by Pith yet. Machine review is queued; the pith claim, tier, and objections will appear here once it completes.

SPECIMEN: schema-true, not a live event

T0 review · schema-true

One-sentence machine reading of the paper's core claim.

pith:XXXXXXXX · record.json · timestamp

arxiv 2003.10405 v3 pith:QQ7C5JIT submitted 2020-03-23 physics.med-ph

Mechanical Ventilator Milano (MVM): A Novel Mechanical Ventilator Designed for Mass Scale Production in Response to the COVID-19 Pandemic

C. Galbiati , A. Abba , P. Agnes , P. Amaudruz , M. Arba , F. Ardellier-Desages , C. Badia , G. Batignani
show 140 more authors
G. Bellani G. Bianchi D. Bishop V. Bocci W. Bonivento B. Bottino M. Bouchard S. Brice G. Buccino S. Bussino A. Caminata A. Capra M. Caravati M. Carlini L. Carrozzi J. M. Cela B. Celano C. Charette S. Coelli M. Constable V. Cocco G. Croci S. Cudmore A. Dal Molin S. D'Auria G. D'Avenio J. DeRuiter S. De Cecco L. De Lauretis M. Del Tutto A. Devoto T. Dinon E. Druszkiewicz A. Fabbri F. Ferroni G. Fiorillo R. Ford G. Foti D. Franco F. Gabriele P. Garcia Abia L. S. Giarratana J. Givoletti Mi. Givoletti G. Gorini E. Gramellini G. Grosso F. Guescini E. Guetre T. Hadden J. Hall A. Heavey G. Hersak N. Hessey An. Ianni C. Ienzi V. Ippolito C. L. Kendziora M. King A. Kittmer I. Kochanek R. Kruecken M. La Commara G. Leblond X. Li C. Lim T. Lindner T. Lombardi T. Long P. Lu G. Lukhanin G. Magni R. Maharaj M. Malosio C. Mapelli P. Maqueo P. Margetak S. M. Mari L. Martin N. Massacret A. McDonald D. Minuzzo T. A. Mohayai L. Molinari Tosatti C. Moretti A. Muraro F. Nati A. J. Noble A. Norrick K. Olchanski I. Palumbo R. Paoletti N. Paoli C. Pearson C. Pellegrino V. Pesudo A. Pocar M. Pontesilli R. Pordes S. Pordes A. Prini O. Putignano J.L. Raaf M. Razeti A. Razeto D. Reed A. Renshaw M. Rescigno F. Retiere L. P. Rignanese J. Rode L. J. Romualdez R. Santorelli D. Sablone E. Scapparone T. Schaubel B. Shaw A.S. Slutsky B. Smith N.J.T. Smith P. Spagnolo F. Spinella A. Stenzler A. Steri L. Stiaccini C. Stoughton P. Stringari M. Tardocchi R. Tartaglia G. Testera C. Tintori A. Tonazzo J. Tseng E. Viscione F. Vivaldi M. Wada H. Wang S. Westerdale S. Yue A. Zardoni
This is my paper
classification physics.med-ph
keywords ventilatormechanicalcovid-19designedmedicalproductioncompresseddevice
verification ladder T0 review T1 audit T2 compute T3 formal T4 reserved
0 comments
read the original abstract

Presented here is the design of the Mechanical Ventilator Milano (MVM), a novel mechanical ventilator designed for rapid mass production in response to the COVID-19 pandemic to address the urgent shortage of intensive therapy ventilators in many countries, and the growing difficulty in procuring these devices through normal supply chains across borders. This ventilator is an electro-mechanical equivalent of the old and reliable Manley Ventilator, and is able to operate in both pressure-controlled and pressure-supported ventilation modes. MVM is optimized for the COVID-19 emergency, thanks to the collaboration with medical doctors in the front line. MVM is designed for large-scale production in a short amount of time and at a limited cost, as it relays on off-the-shelf components, readily available worldwide. Operation of the MVM requires only a source of compressed oxygen (or compressed medical air) and electrical power. Initial tests of a prototype device with a breathing simulator are also presented. Further tests and developments are underway. At this stage the MVM is not yet a certified medical device but certification is in progress.

discussion (0)

Sign in with ORCID, Apple, or X to comment. Anyone can read and Pith papers without signing in.