Pith. sign in

REVIEW

A Feasibility Study on Deep Learning-Based Radiotherapy Dose Calculation

Not yet reviewed by Pith; the record is open.

This paper has not been read by Pith yet. Machine review is queued; the pith claim, tier, and objections will appear here once it completes.

SPECIMEN: schema-true, not a live event

T0 review · schema-true

One-sentence machine reading of the paper's core claim.

pith:XXXXXXXX · record.json · timestamp

arxiv 1908.03159 v1 pith:NATHJGAT submitted 2019-08-08 physics.med-ph

A Feasibility Study on Deep Learning-Based Radiotherapy Dose Calculation

classification physics.med-ph
keywords dosecalculationdistributionimrtaccuratealgorithmsdeepdomain
verification ladder T0 review T1 audit T2 compute T3 formal T4 reserved
0 comments
read the original abstract

Purpose: Various dose calculation algorithms are available for radiation therapy for cancer patients. However, these algorithms are faced with the tradeoff between efficiency and accuracy. The fast algorithms are generally less accurate, while the accurate dose engines are often time consuming. In this work, we try to resolve this dilemma by exploring deep learning (DL) for dose calculation. Methods: We developed a new radiotherapy dose calculation engine based on a modified Hierarchically Densely Connected U-net (HD U-net) model and tested its feasibility with prostate intensity-modulated radiation therapy (IMRT) cases. Mapping from an IMRT fluence map domain to a 3D dose domain requires a deep neural network of complicated architecture and a huge training dataset. To solve this problem, we first project the fluence maps to the dose domain using a modified ray-tracing algorithm, and then we use the HD U-net to map the ray-tracing dose distribution into an accurate dose distribution calculated using a collapsed cone convolution/superposition (CS) algorithm. Results: It takes about one second to compute a 3D dose distribution for a typical 7-field prostate IMRT plan, which can be further reduced to achieve real-time dose calculation by optimizing the network. For all eight testing patients, evaluation with Gamma Index and various clinical goals for IMRT optimization shows that the DL dose distributions are clinically identical to the CS dose distributions. Conclusions: We have shown the feasibility of using DL for calculating radiotherapy dose distribution with high accuracy and efficiency.

discussion (0)

Sign in with ORCID, Apple, or X to comment. Anyone can read and Pith papers without signing in.