Pith. sign in

REVIEW

Optical-SZE Scaling Relations for DES Optically Selected Clusters within the SPT-SZ Survey

Not yet reviewed by Pith; the record is open.

This paper has not been read by Pith yet. Machine review is queued; the pith claim, tier, and objections will appear here once it completes.

SPECIMEN: schema-true, not a live event

T0 review · schema-true

One-sentence machine reading of the paper's core claim.

pith:XXXXXXXX · record.json · timestamp

arxiv 1605.08770 v1 pith:OHT3NO6Y submitted 2016-05-27 astro-ph.CO

Optical-SZE Scaling Relations for DES Optically Selected Clusters within the SPT-SZ Survey

classification astro-ph.CO
keywords clusterslambdarelationssignalcalibratedlargermeasuredrelation
verification ladder T0 review T1 audit T2 compute T3 formal T4 reserved
0 comments
read the original abstract

We study the Sunyaev-Zel'dovich effect (SZE) signature in South Pole Telescope (SPT) data for an ensemble of 719 optically identified galaxy clusters selected from 124.6 deg$^2$ of the Dark Energy Survey (DES) science verification data, detecting a stacked SZE signal down to richness $\lambda\sim20$. The SZE signature is measured using matched-filtered maps of the 2500 deg$^2$ SPT-SZ survey at the positions of the DES clusters, and the degeneracy between SZE observable and matched-filter size is broken by adopting as priors SZE and optical mass-observable relations that are either calibrated using SPT selected clusters or through the Arnaud et al. (2010, A10) X-ray analysis. We measure the SPT signal to noise $\zeta$-$\lambda$, relation and two integrated Compton-$y$ $Y_\textrm{500}$-$\lambda$ relations for the DES-selected clusters and compare these to model expectations accounting for the SZE-optical center offset distribution. For clusters with $\lambda > 80$, the two SPT calibrated scaling relations are consistent with the measurements, while for the A10-calibrated relation the measured SZE signal is smaller by a factor of $0.61 \pm 0.12$ compared to the prediction. For clusters at $20 < \lambda < 80$, the measured SZE signal is smaller by a factor of $\sim$0.20-0.80 (between 2.3 and 10~$\sigma$ significance) compared to the prediction, with the SPT calibrated scaling relations and larger $\lambda$ clusters showing generally better agreement. We quantify the required corrections to achieve consistency, showing that there is a richness dependent bias that can be explained by some combination of contamination of the observables and biases in the estimated masses. We discuss possible physical effects, as contamination from line-of-sight projections or from point sources, larger offsets in the SZE-optical centering or larger scatter in the $\lambda$-mass relation at lower richnesses.

discussion (0)

Sign in with ORCID, Apple, or X to comment. Anyone can read and Pith papers without signing in.