Pith. sign in

REVIEW

On the parameters affecting dual-target-function evaluation of single-particle selection from cryo-electron micrographs

Not yet reviewed by Pith; the record is open.

This paper has not been read by Pith yet. Machine review is queued; the pith claim, tier, and objections will appear here once it completes.

SPECIMEN: schema-true, not a live event

T0 review · schema-true

One-sentence machine reading of the paper's core claim.

pith:XXXXXXXX · record.json · timestamp

arxiv 1509.06863 v1 pith:ZTZH4VAQ submitted 2015-09-23 q-bio.QM

On the parameters affecting dual-target-function evaluation of single-particle selection from cryo-electron micrographs

classification q-bio.QM
keywords imagesmicrographssingle-particleapproachdataparticleparticlesratio
verification ladder T0 review T1 audit T2 compute T3 formal T4 reserved
0 comments
read the original abstract

In the analysis of frozen hydrated biomolecules by single-particle cryo-electron microscopy, template-based particle picking by a target function called fast local correlation (FLC) allows a large number of particle images to be automatically picked from micrographs. A second, independent target function based on maximum likelihood (ML) can be used to align the images and verify the presence of signal in the picked particles. Although the paradigm of this dual-target-function (DTF) evaluation of single-particle selection has been practiced in recent years, it remains unclear how the performance of this DTF approach is affected by the signal-to-noise ratio of the images and by the choice of references for FLC and ML. Here we examine this problem through a systematic study of simulated data, followed by experimental substantiation. We quantitatively pinpoint the critical signal-to-noise ratio (SNR), at which the DTF approach starts losing its ability to select and verify particles from cryo-EM micrographs. A Gaussian model is shown to be as effective in picking particles as a single projection view of the imaged molecule in the tested cases. For both simulated micrographs and real cryo-EM data of the 173-kDa glucose isomerase complex, we found that the use of a Gaussian model to initialize the target functions suppressed the detrimental effect of reference bias in template-based particle selection. Given a sufficient signal-to-noise ratio in the images and the appropriate choice of references, the DTF approach can expedite the automated assembly of single-particle data sets.

discussion (0)

Sign in with ORCID, Apple, or X to comment. Anyone can read and Pith papers without signing in.